Ransburg, Specifications, Environmental / physical – Ransburg MicroPak Controller A11789 User Manual
Page 9: Electrical micropak controller - introduction
DC Power Required: *
(per MicroPak)
24VDC at 2.5A
(fully loaded output),
HP404 Cascade
AC Electrical Requirements:
90-264 VAC @ 1.5 amps @
47/63 Hertz
* DC power supplied from 24VDC built-in,
regulated power supy which has over-current
(40%) and over-voltage (20%) protection.
Controls:
Discrete signals available via I/O Module
(Part #76037-03)
Analog In:
KV SET (0-10VDC)
OVER-CURRENT SET
(0-10VDC)
Discrete Out:
HV ON (+24V)
HV READY (+24V)
OVER-CURRENT FAULT
(+24V)
Discrete In:
HV RESET (+24V)
HV ON (+24V)
Temp. Operating: (0o to 55o C)
Storage: (-40o C to 85o C)
Humidity: (95% Non-Condensing)
Cabinet Size: 13” Wide
19” Deep
7” Height
Weight: 19 lbs.
SPECIFICATIONS
(At Sea-Level Conditions)
Environmental / Physical
NOTES
Electrical
MicroPak Controller - Introduction
7
Ransburg
CP-06-01.1