Ransburg, Specifications, Environmental / physical – Ransburg MicroPak Controller A11789 User Manual

Page 9: Electrical micropak controller - introduction

Advertising
background image

DC Power Required: *

(per MicroPak)

24VDC at 2.5A

(fully loaded output),

HP404 Cascade

AC Electrical Requirements:

90-264 VAC @ 1.5 amps @

47/63 Hertz

* DC power supplied from 24VDC built-in,

regulated power supy which has over-current

(40%) and over-voltage (20%) protection.

Controls:

Discrete signals available via I/O Module

(Part #76037-03)
Analog In:

KV SET (0-10VDC)

OVER-CURRENT SET

(0-10VDC)
Discrete Out:

HV ON (+24V)

HV READY (+24V)

OVER-CURRENT FAULT

(+24V)
Discrete In:

HV RESET (+24V)

HV ON (+24V)

Temp. Operating: (0o to 55o C)

Storage: (-40o C to 85o C)
Humidity: (95% Non-Condensing)
Cabinet Size: 13” Wide

19” Deep

7” Height
Weight: 19 lbs.

SPECIFICATIONS

(At Sea-Level Conditions)

Environmental / Physical

NOTES