AIR FILTRATION
REQUIRMENTS
It is the user's responsibility to insure clean, dry air at
all times. Turbine failure resulting from contaminated
air will not be covered under warranty. The following
pre-filter and bearing air filter(s) (see Figure 5) are
recommended for use in Aerobell Copes systems. See
Figure 5 if other filters are incorporated in the system
- the filters to be used must have filtering capacities
equal to or greater than those shown in Figure 5.
PSI RPM (unloaded) SCFM
60,000 (max.)
56,000
52,600
48,300
43,400
37,700
31,000
23,000
13,000
18.0
15.8
14.2
13.0
11.4
9.7
7.9
6.1
3.9
Figure 4: Turbine Air Pressure / RPM / SCFM
Aerobell Copes - Introduction
>
Air must be properly filtered to assure ex-
tended turbine life and to prevent contamina-
tion of the paint job. Air which is not adequately
filtered will foul the turbine air bearings and cause
turbine failure. The correct type of filters must
be used in an Aerobell Copes system. The filter
elements must be replaced on a regular schedule
to assure clean air.
C A U T I O N
!
8
Ransburg
Filter Model No.
HAF-503
RPM-417
RPM-418
HAF-15 Element, One
RPM-32 Elements,
Carton of 4
RPM-33 Elements,
Carton of 8
Pre-filter, removes coarse amounts of oil, moisture &
dirt. Used upstream of RPM-417 pre-filter (used in
systems with poor air quality).
Pre-filter, coalescing type, 136 scfm, 98.5% efficiency
particulate removal .3 to .6 micron, max. aerosol passed
1.0 micron, max. solid passed .4 micron (dependent upon
scfm requirement per applicator).
Bearing air filter, coalescing type, 19 scfm, 99.995%
efficiency particulate removal .3 to .6 micron, max. aerosol
passed .6 micron, max. solid passed .2 micron (one per
applicator).