Aerobell Copes - Maintenance

MAINTENANCE

In addition to the above Warning, which relates to

potential safety hazards, the following information

must be observed to prevent damage to the

equipment.

>

Electrical shock/arcing and potential fire

hazards can exist during maintenance. The

high voltage must be turned OFF before enter-

ing the spray area and performing any mainte-

nance procedures. Spray booth exhaust fans(s)

should remain ON while cleaning the equip-

ment with solvents.

>

Never touch the atomizer bell while it is

spinning. The front edge can easily cut into

human skin. Make sure the atomizer bell has

stopped spinning before attempting to touch

it. Wait at least three minutes after turbine

drive air is OFF before touching the bell.

The precise sequence of flushing paint from the

system will vary according to the type of color valve

arrangement used and other automatic features

built into the system. Follow these basic procedures

when cleaning:

18

CLEANING PROCEDURES

1.

Verify high voltage is OFF. The high voltage

must be turned OFF before performing any

maintenance.

2.

With the bearing air and turbine air ON, flush

paint out with solvent. Flushing should be

done before any break in production. If

the Aerobell Copes is mounted facing up,

rotate to a horizontal plane before flushing

or cleaning.

3.

Flushing should be done with the atomizer

bell installed. The bell includes a self cleaning

feature, and the bell will normally be fully

cleaned with flushing. However, if there is any

remaining paint build up on any areas of the

bell after flushing, the bell should be removed

and cleaned by hand (see 4 below).

4.

Clean the bell by soaking in an appropriate

solvent as long as necessary to loosen paint.

Use a soft bristle brush dipped in solvent to

remove paint. Make sure all signs of paint are

removed. See Caution below. Rinse and dry

bell.

5.

Before re-installing the bell onto the shaft,

check the tapered mating surfaces of the

turbine shaft and bell for any paint residue.

Clean any residue. See Caution below.

LN-9230-00.1

W A R N I N G

!

>

Do not immerse the Aerobell Copes

turbine in solvent or other liquids. Turbine

components will be damaged.

>

Bearing air must be ON during all cleaning

procedures.

>

Do not spray the Aerobell Copes unit with

a solvent gun for cleaning. Dousing or spray-

ing the applicator and Aerobell Copes compo-

nents with solvent before wiping will not help

to loosen paint.

C A U T I O N

!

>

Using an atomizer bell with paint build up

will cause a bell imbalance. An imbalanced

bell may cause bearing damage and turbine

failure. Also, any paint residue caught between

the tapered surfaces can prevent the bell from

seating properly and result in an imbalanced

condition.

>

Never install an atomizer bell onto the

shaft without cleaning the fluid tube tip. Paint

build-up on the tip may get caught in the

thread relief of the bell during installation.

C A U T I O N

!