Coating material conductivity – Ransburg Aerobell Copes 75850 User Manual

Page 20

Advertising
background image

Aerobell Copes - Operation

ELECTRODE REMOVAL

PROCEDURE FOR OPTIONAL

DIRECT CHARGING METHOD

-REFER TO FIGURE 8

1.

Verify that high voltage is OFF. The

high voltage must be turned OFF before

performing any maintenance.

2.

Remove item 7 (13521-03, compression nut)

and high voltage cable from port marked

HV.

3.

Remove item 22i (13521-03, compression nut)

and ground cable from port marked GND.

4.

Remove item 14 (14061-02, conductive foam

insert), item 13 (76562-00, spring loaded

contact pin screw assembly), item 12 (75841-

00, high voltage cable support tube) and item

9 (LSOR0007-06, O-Ring) from port marked

HV.

5.

Remove item 5 (Qty-6, 75847-00, electrode

body retaining nuts) and item 6 (Qty-6, 76719-

00, electrode body assemblies).

6.

Remove item 3 (Qty-20, M5 x 40mm long,

slotted fillister head screws) and item 4 (Qty-

5, 75854-02, 90

° connector electrode body

assembly.) Items 3 and 4 (marked “B”) must

be removed prior to removing items 3 and

15 (marked “A”).

7.

Remove item 3 (Qty-4, M5 x 40mm long,

slotted fillister head screws) and item 15

(75854-01, 90

° connector electrode body

assembly.) Unit damage may occur if items

3 and 15 (marked “A”) are removed prior to

disassembly of items 9, 12, 13 and 14 (marked

“C”) and items 3 and 4 (marked “B”).

8.

Install item 9 (LSOR0007-06, O-Ring), item 12

(75841-00, high voltage cable support tube)

and item 7 (13521-03, compression nut) into

port marked HV.

9.

Install 73033-20F, 1/4-28 x 5/8 long nylon

socket head cap screw (not shown), into item

12 (75841-00, high voltage cable support

tube). Torque screw to 3-5 inch pounds.

10.

Install 1/4 dia. x 3" long nylon rod (non-

conductive) material (not shown) into item 12

(75841-00, high voltage cable support tube)

and tighten item 7 (13521-03, compression

nut).

11.

Install S10364-00, (Qty-6, 90

° connector port

cap, not shown), LSOR0007-05, (Qty-6, o-ring,

not shown) and item 3 (Qty-24, M5 x 40mm,

long slotted fillister head screws) in ports

marked A and B. Torque screws to 3-5 inch

pounds. Unit damage may occur if screws

are over torqued.

12.

Install high voltage cable into port marked

GND and tighten item 22i (13521-03,

compression nut).

16

COATING MATERIAL

CONDUCTIVITY

The Aerobell Copes can be used with a full range of

conductive coatings including solvent-borne and

waterborne materials. Charging methods include:

• Indirect charge for use with waterborne, grounded

fluid systems. The fluid system, including the

applicator, are connected to ground potential and

voltage is applied to the external electrodes. (See

Figure 8.)

• Direct charge for use with solventborne, grounded

fluid systems with electrodes removed. The fluid

system is connected to ground potential and

voltage is applied to the applicator. (See Figure

8.)

• Direct charge for use with waterborne, isolated fluid

systems with electrodes removed. The fluid system

is isolated from ground potential and voltage is

applied to the applicator. (See Figure 8.)

LN-9230-00.1