Motor Disassembly

1.

Remove 76757-00, shaping air ring cap,
76756-00, shaping air ring from the shroud
and the atomizer bell from the turbine shaft
(refer to “Atomizer Bell Removal” on page
22.)

2.

Remove shroud by removing the three 76748-
12F, fillister head screw, using medium flat
head screwdriver. Shroud can then be pulled
forward.

Aerobell Copes Turbine

Disassembly & Repair

Disassembly and repair of the Turbine is covered in
Service Reference SR-70-52-1 (latest issue). When
returning the air bearing turbine to Ransburg for
repair, return the Quick Change Motor Assembly or
turbine only.

Copes Quick Change Aerobell

Motor Reassembly

1.

Reassemble the shroud, atomizer bell,
shaping air ring and cap onto the Quick
Change Motor Assembly by reversing the
above instructions.

2.

Before installing the Quick Change Assembly
back into the manifold, check the condition
of the four-coated o-rings located on the
four air fittings of the manifold. If any are
damaged or missing, replace them.

Aerobell Copes - Maintenance

23

AEROBELL COPES TURBINE

MAINTENANCE & REPAIR ITEMS

Figure 10: Pre-packaged Repair Kits

Kit Part No.

KK-4461

KK-4462

KK-4463

RPM-33

RPM-32

Description

Turbine Repair Kit
(for on-site turbine repair)
Rotor Screw Kit
(for on-site turbine repair)
Turbine Screw Kit
(for on-site turbine repair)
Bearing Air Filter Element Kit
(box of 8)
Pre-filter Element Kit
(box of 4)

3.

Check the condition of the SSG-8128, o-ring,
located on the fluid inlet on the rear of the
turbine. Replace if damaged or missing.
Lightly lubricate the SSG-8128, o-ring, with
petroleum jelly.

4.

Install the Quick Change Motor Assembly
onto the manifold. Align properly (it is
easiest to align the shaping air fitting which
is furthest from the center line). Press the
Quick Change Assembly straight forward as
much as possible (don’t force it on).

5.

Tighten 75844-00, retaining nut, CW which
will draw the quick change motor assembly
fully into place with the manifold.