5.

After installation and wiring have been completed, re-install the lock cover through the lock chassis
using the two (2) Phillips screws removed in the first step.

MAGNALOCK MAINTENANCE
Visual Inspection

Check the rubber washers for elasticity and proper pivoting. Tighten as required.

Check for build-up of debris on the Magnalock and strike armature.

Check for rust on the Magnalock and strike plate armature. Clean as required.

Cleaning Methods

Apply rubbing alcohol onto a clean cloth and thoroughly wipe down the Magnalock and strike plate
armature.

Cleaning once a year is recommended.

Clean every three to six months where rusting occurs.

Use a plastic dishwashing scrub pad to aid in the removal of rust.

DO NOT USE PETROLEUM BASED PRODUCTS FOR CLEANING
DO NOT USE STEEL WOOL BASED SCRUB PAD OR SANDPAPER