Installation

1.

C
H
1

Remove two (2) screws securing lock to mounting
bracket and slide the bracket from the top of the
lock chassis.

2.

Pinch and insert spacers flush into the dovetail slots of

the lock-mounting bracket.
(These spacers maintain a distance of approximately
2-3/16” from the face of the door to the back edge of
the bracket).

3.

Mark Mounting Holes:

Use masking tape to protect the door and frame surfaces during marking and drilling.
Place the lock bracket on the secure side of the door against the frame stop toward the side of the
door that does not have hinges. Close the door and adjust the bracket so that the spacers rest
against the door. Mark the frame through the two (2) oblong bracket mounting holes.
Note: Maintain 1” minimum clearance from the frame

4.

Mark Wire Feed-Through Holes:

Mark the frame for wire feed-through hole at the end closest to where you will access the wire run.
These holes should be toward the rear edge of the mounting bracket and be adjacent to the end of
the bracket as shown. Remove mounting bracket from frame when drilling holes.

Quick Clip 2:

Mounting the

Bracket

1” (MIN.)

Use either/both location(s) for 1/2” diameter Wire Feed-Through Holes