Troubleshooting Guide:

POSSIBLE ISSUES

TROUBLESHOOTING TIPS

No power or low power

Confirm voltage and current at Magnalock to spec
(see page 2)
Check that the DC Power Source is Full Wave Rectified
(Half wave Rectified or AC power is unacceptable)

Reduced Holding Force

Check strike plate position and orientation
Clean surfaces and check for obstructions

LED Error Codes:

Note: The position 1 switch of DIP switch SW3 must be set to the ON position (LED ENABLED) for error
codes to be visible.

CODE

STATE

SOLUTION

SECURE selected color,
on continuously

Normal Operation with
Door Closed

System working normally, SECURE selected
color can be selected with position 2 switch
of SW3. See page 4.

NON-SECURE selected
color, on continuously

Normal Operation with
Door Open

System working normally.

RED/GREEN continuous
flash

Processor Error

Check all connections, if error persists
replace unit.

3 Fast Flashes of
SECURE color every 5
seconds

Magnet Voltage has
dropped below 85%

Check voltage and current at Magnalock
connections. Check DC Power Source is Full
Wave Rectified.

Single Flash Amber
every 5 seconds

Bond Error – Left Side

Check strike plate position and orientation.
Clean surfaces and check for obstructions.

Double Flash Amber
every 5 seconds

Bond Error – Right Side

Check strike plate position and orientation.
Clean surfaces and check for obstructions.

Off

LED disabled

Check voltage and current at Magnalock
connections. Check that LED is enabled with
position 1 switch of SW3 in the OFF position.