PN# 500-23310

Page 7

Rev. B 06/14

SW1

DIP Switch SW1.4:
PIR Ambient Light
Compensation

Can be enabled with
SW1.4

Ambient Light
Compensation Off

(default)

Position 4
Off

Position 4
OFF

Ambient Light
Compensation ON

Position 4
ON

Position 4
ON

SW1

DIP Switch SW1.5:
External PIR Input
External input at J6 can
be enabled at SW1.5

DISABLE External PIR
Input

Position 5 OFF (default)

ENABLE External PIR
Input

Position 5 ON

JP1

Jumper 1: Alternate
(REX) Output

A 3-pin jumper that
controls the output
setting for Alternate
(REX) Output at
Terminal Block J7.

(NC) Normally Closed
Circuit Closed, Circuit opens
when REX active (default
setting)

(NO) Normally Open
Circuit Open, Circuit closes
when REX active

JP3

Jumper 3:
BondSTAT
Mode Select

A 3-pin jumper that
controls the output
setting for the
BondSTAT in Terminal
Block J8 Position 1 & 2.

(NC) Normally Closed
Circuit Closed when Door is
Closed (default setting)

(NO) Normally Open
Circuit Open when Door is
Closed

JP4

Jumper 4:
Door Position
Mode Select

A 3-pin jumper that
controls the output
setting for the Door
Position Switch (DPS)
in Terminal Block J12
Position 1 & 2.

(NC) Normally Closed
Circuit Closed when Door is
Closed (default setting)

(NO) Normally Open
Circuit Open when Door is
Closed

J9

Terminal Block 9
Tamper Switch

A 2-wire terminal block providing a signal which changes
state as determined when the cover is sensed to be
removed. (Circuit is Normally Closed with cover in place).

J3

Terminal Block 3
Magnalock Input
Power

A 2-wire terminal block providing connection to a 12 or 24
VDC power supply for the main Magnalock operation.
Position 1 = (+) Positive. Position 2 = (-) Negative.

J2

Terminal Block 2
Auxiliary Input
Power

A 2-wire terminal block providing connection to the power
supply for the auxiliary components (PIR and/or Camera).
Position 1 = (+) Positive. Position 2 = (-) Negative.