are what are called ‘insulation displacement connectors’. These simply snap on to an entire
cable, automatically ‘displacing’ the wire insulation and making contact with the wires within.
This means that an entire 40 wire cable can be terminated in seconds. All connectors are po-
larized, to keep them from being plugged in backwards.

Each J6/A cable is arranged in the following order:

wire number

color

wire function

1

brown

circuit ground

2

red

+ unregulated power supply (protected to 1 amp)

3

orange

Output 15 (0Fh) Positive Analog Output

4

yellow

Output 15 (0Fh) Negative Reference

5

green

Output 14 (0Eh) Positive Analog Output

6

blue

Output 14 (0Eh) Negative Reference

7

violet

Output 13 (0Dh) Positive Analog Output

8

gray

Output 13 (0Dh) Negative Reference

9

white

Output 12 (0Ch) Positive Analog Output

10

black

Output 12 (0Ch) Negative Reference

11

brown

circuit ground

12

red

+ unregulated power supply (protected to 1 amp)

13

orange

Output 11 (0Bh) Positive Analog Output

14

yellow

Output 11 (0Bh) Negative Reference

15

green

Output 10 (0Ah) Positive Analog Output

16

blue

Output 10 (0Ah) Negative Reference

17

violet

Output 9 (09h) Positive Analog Output

18

gray

Output 9 (09h) Negative Reference

19

white

Output 8 (08h) Positive Analog Output

20

black

Output 8 (08h) Negative Reference

21

brown

circuit ground

22

red

+ unregulated power supply (protected to 1 amp)

23

orange

Output 7 (07h) Positive Analog Output

24

yellow

Output 7 (07h) Negative Reference

25

green

Output 6 (06h) Positive Analog Output

26

blue

Output 6 (06h) Negative Reference

27

violet

Output 5 (05h) Positive Analog Output

28

gray

Output 5 (05h) Negative Reference

29

white

Output 4 (04h) Positive Analog Output

30

black

Output 4 (04h) Negative Reference

31

brown

circuit ground

32

red

+ unregulated power supply (protected to 1 amp)

33

orange

Output 3 (03h) Positive Analog Output

34

yellow

Output 3 (03h) Negative Reference

35

green

Output 2 (02h) Positive Analog Output

36

blue

Output 2 (02h) Negative Reference

37

violet

Output 1 (01h) Positive Analog Output

38

gray

Output 1 (01h) Negative Reference

39

white

Output 0 (00h) Positive Analog Output

40

black

Output 0 (00h) Negative Reference

Analog loads are connected between each of the Positive outputs and its associated

Negative reference. The output capacity of each output is 20 ma. The output voltage range
can be adjusted from the FSK/RTU to anywhere between 0 and 10 volts. Current amplifiers are
available if additional current capacity is required for your application.

The negative reference is at a voltage of approximately 1.6 volts above the circuit ground.

The negative references are all connected on the FSK/RTU, but there must be no direct con-
nections made between any of the negative references and the circuit grounds anywhere
in the animation system
.