for transmitting a checksum. The FSK/RTU can use this to verify that the data received from
PC•MACs has no transmission errors in it. If you address a FSK/RTU or other DMX-512 device to
addresses 256 or 257, you will see this verification data displayed as a flickering pattern. Note
that at frame rates higher than 40 FPS, not all 256 channels will be transmitted through the
DMX-512 output.

The positive and negative DMX-512 wires are attached to the FSK/RTU through the screw

terminals marked on its back. The shield (if any) can be attached to the ground side of the
power supply terminal.

E) Four J-6 connectors for Digital Data Output:

In all the animation systems made by

Gilderfluke & Company, all digital input and output cabling is through what we call ‘J6’ stan-
dard output cables. These are 40 wire cables which are made up of four identical eight bit
wide ‘channels’. A J6 cable is often split up into four individual channels. Each ‘1/4 J6’ cable is
made up of 10 wires, and can be used to control eight individual ‘digital’ (off/on) devices, or
one eight bit wide ‘analog’ device. The remaining two wires in each 1/4 J6 are used for
ground and a power connection.

In all the animation systems made by Gilderfluke & Company, all digital outputs are open

collector switches to ground, and all digital inputs are through optoisolators. Flyback diodes
are included in the outputs for driving inductive loads:

typical output

typical input

fuse

flyback

diode

supply

supply

To simplify wiring to any of our animation systems, the connectors used on the J6 cables

are what are called ‘insulation displacement connectors’. These simply snap on to an entire
cable, automatically ‘displacing’ the wire insulation and making contact with the wires within.
This means that an entire 40 wire cable can be terminated in seconds. All connectors are po-
larized, to keep them from being plugged in backwards.

Each J6 cable is arranged in the following order:

wire number

color

wire function

1

brown

circuit ground

2

red

channel 0 data bit 7

3

orange

channel 0 data bit 6

4

yellow

channel 0 data bit 5

5

green

channel 0 data bit 4

6

blue

channel 0 data bit 3

7

violet

channel 0 data bit 2

8

gray

channel 0 data bit 1

9

white

channel 0 data bit 0

10

black

+ unregulated power supply (protected to 1 amp)

11

brown

circuit ground

12

red

channel 1 data bit 7

13

orange

channel 1 data bit 6

14

yellow

channel 1 data bit 5

15

green

channel 1 data bit 4

16

blue

channel 1 data bit 3

G

ILDERFLUKE

& C

O

. • 205 S

OUTH

F

LOWER

S

T

. • B

URBANK

, C

ALIF

. 91502-2102 • 818/840-9484 •

FAX

818/840-9485