Main Configuration Screens:

-Gilderfluke & Company - RTU/FSK Controller - version 2.00 - copyright 1994 DCM-

sequencer = 20h x 06450 frames forced forced forced analog analog delay

ON OFF analog min. max. seconds

a) tape deck pulse- 0.5 seconds 0:______|______|______|__00__|__FF__|__0000__|
b) FSK/DMX dropout- 1.0 seconds 1:______|______|______|__00__|__FF__|__0015__|
c) FSK intershow- 10 seconds 2:______|______|______|__00__|__FF__|__0030__|
d) FSK startup- 20 seconds 3:______|______|______|__00__|__FF__|__0045__|
e) minimum rewind- 0030 seconds 4:______|______|______|__00__|__FF__|__0060__|
f) set FSK time delays 5:______|______|______|__00__|__FF__|__0090__|
g) enter strings 6:______|______|______|__00__|__FF__|__0120__|
h) sequencer enabled- yes 7:______|______|______|__00__|__FF__|__0180__|
i) countdown displayed- yes 8:______|______|______|__00__|__FF__|__0240__|
j) force digital outputs off 9:______|______|______|__00__|__FF__|__0300__|
k) force digital outputs on A:______|______|______|__00__|__FF__|__0450__|
l) force analog to a value B:______|______|______|__00__|__FF__|__0600__|
n) set analog endpoints C:______|______|______|__00__|__FF__|__0900__|
r) download configuration D:______|______|______|__00__|__FF__|__1200__|
s) upload configuration E:______|______|______|__00__|__FF__|__1500__|
t) default configuration F:______|______|______|__00__|__FF__|__1800__|
u) Read configuration from EEPROM
w) Write configuration to EEPROM | x) eXit

countdown- 0000 | dropout timer- 00 | intershow timer- 00 | startup timer- 00

If the FSK/RTU is set for receiving DMX-512 data, the following menu will be displayed instead. It differs

from the first only in that several of the commands and settings which are specific to the FSK data have
been disabled.

-Gilderfluke & Company - RTU/FSK Controller - version 2.00 - copyright 1994 DCM-

sequencer = 20h x 06450 frames forced forced forced analog analog

ON OFF analog min. max.

0:______|______|______|__00__|__FF__|

b) FSK/DMX dropout- 1.0 seconds 1:______|______|______|__00__|__FF__|

2:______|______|______|__00__|__FF__|
3:______|______|______|__00__|__FF__|
4:______|______|______|__00__|__FF__|
5:______|______|______|__00__|__FF__|
6:______|______|______|__00__|__FF__|

h) sequencer enabled- yes 7:______|______|______|__00__|__FF__|

8:______|______|______|__00__|__FF__|

j) force digital outputs off 9:______|______|______|__00__|__FF__|
k) force digital outputs on A:______|______|______|__00__|__FF__|
l) force analog to a value B:______|______|______|__00__|__FF__|
n) set analog endpoints C:______|______|______|__00__|__FF__|
r) download configuration D:______|______|______|__00__|__FF__|
s) upload configuration E:______|______|______|__00__|__FF__|
t) default configuration F:______|______|______|__00__|__FF__|
u) Read configuration from EEPROM
w) Write configuration to EEPROM | x) eXit

command-

On either of these menus, the size of the sequencer EPROM installed (if any)is also shown near the top

of the screen. If the sequencer EPROM isn’t found, then this area will not appear on the screen.

If another command is entered while the last command is waiting for additional input, the new com-

mand will be started. If at any point you enter a command in error and it is waiting for additional input,
you can leave the command by entering an <ESC>ape key. You can also bail from the string entry com-