C. OPTIONAL EQUIPMENT

Below is a list of optional equipment available from HTP:

Indirect Tank Sensor (Part # 7250P-325)

Outdoor sensor (Part # 7250P-319)

2” Stainless Steel Outside Termination Vent Kit (V500)

3” Stainless Steel Outside Termination Vent Kit (V1000)

2” PVC Concentric Vent Kit (Part # KGAVT0501CVT)

3" PVC Concentric Vent Kit (Part # KGAVT0601CVT)

3” Polypro Vent Kit (Part # 8400P-001)

3” Polypro Pipe (33’ length Part # 8400P-002, 49.5’ length Part # 8400P-003)

U.L. 353 Compliant Low Water Cut-Off Interface Kit with Manual Reset (Part # 7450P-225)

Alarm System (Part # 7350P-602) (to monitor any failure)

Condensate Pump (Part # 554200)

Condensate Neutralizer (Part # 7450P-218)

Vision 1 Outdoor Sensing System (Part # 7250P-622)


These additional options may be purchased through your HTP distributor.

PART 3 – PREPARE BOILER LOCATION

Carefully consider installation when determining boiler location. Please read the entire manual before attempting installation. Failure to
properly take factors such as boiler venting, piping, condensate removal, and wiring into account before installation could result in
wasted time, money, and possible property damage and personal injury.

A. BEFORE LOCATING THE BOILER

Incorrect ambient conditions can lead to damage to the heating system and put safe operation at risk. Ensure that the boiler installation
location adheres to the information included in this manual. Failure to do so could result in property damage, serious personal injury, or
death.

Failure of boiler or components due to incorrect operating conditions IS NOT covered by product warranty.

1. Installation Area (Mechanical Room) Operating Conditions

Ensure ambient temperatures are higher than 32

o

F/0

o

C and lower than 104

o

F/40

o

C.

Prevent the air from becoming contaminated by the products, places, and conditions listed in this manual, Part 3, Section F.

Avoid continuously high levels of humidity

Never close existing ventilation openings

The service life of the boiler

’s exposed metallic surfaces, such as the casing, as well as internal surfaces, such as the heat exchanger,

are directly influenced by proximity to damp and salty marine environments. In such areas, higher concentration levels of chlorides from
sea spray coupled with relative humidity can lead to degradation of the heat exchanger and other boiler components. In these
environments, boilers must not be installed using direct vent systems which draw outdoor air for combustion. Such boilers must be
installed using room air for combustion. Indoor air will have a much lower relative humidity and, hence, potential corrosion will be
minimized.

This boiler is certified for indoor installations only. Do not install the boiler outdoors. Failure to install this boiler indoors could result in
substantial property damage, severe personal injury, or death.

2. Check for nearby connections to:

System water piping

Venting connections

Gas supply piping

Electrical power