1. Specifications Check

22

1.2.7 Duty Ratio in Continuous Operation

[1] RCP2

Operation can be performed with the duty ratio 100%.

Duty ratio is the rate of operation expressed in % that presents the time of the actuator being operated in

1 cycle of operation.

[2] RCA

Perform an operation with the duty ratio below the allowable range.

Caution: If the overload error occurs, try either to reduce the duty by extending the stop time or to

reduce the acceleration/deceleration speed.

[How to Calculation Duty]
Figure out the load ratio and acceleration/deceleration time ratio, and read the duty ratio from the graph.
If the load ratio if less than 50%, operation with 100% of the duty ratio (continuous operation) is
available.
1) Duty ratio LF

The maximum transportable weight at the rated acceleration and the rated acceleration/deceleration

speed are described in 1.2 Specifications.

Duty ratio:LF䋽

[%]

Max. Transportable Weight at Rated Acceleration : Mr [kg]

Rated Acceleration/Deceleration Speed

: Dr [G]

Transported Weight during Operation

: M [kg]

Acceleration/Deceleration Speed during Operation : D [G]

2) Acceleration/Deceleration Time Ratio t

od

Acceleration/Deceleration Time Ratio t

od

=

Acceleration Time during Operation + Deceleration Time during Operation

Deceleration time

[%]

Acceleration time =

Speed during Operation[mm/s]

Acceleration during Operation[mm/s

2

]

Sec䌝

Deceleration time =

Speed during Operation [mm/s]

Deceleration during Operation [mm/s

2

]

Sec䌝

Acceleration [mm/s

2

] = Acceleration [G] u 9,800mm/s

2

Deceleration [mm/s

2

] = Deceleration [G] u 9,800mm/s

2

Advertising