Warning – IAI America IX-NSN6016 User Manual

Page 50

Advertising
background image

44

6. Inspection/Maintenance

(6)

Press the emergency-stop switch.

(7)

Set an adjustment jig (pin) in arm 1 or 2 to fix the arm at the reference position.
x Set the jig after confirming that the emergency-stop switch is pressed.
x Set the jig after adjusting the arm to the reference position, using the positioning mark label as a

guide.

x Arm 1 has a cover (not arm 2), which is fixed with setscrews. Remove the setscrews and detach

the cover before setting the jig.

x It is recommended that an adjustment jig be used to perform an absolute reset. With arm 1 or 2,

however, rotation data can be reset as long as a positioning accuracy of “center of positioning mark
label

r1 graduation” is ensured.

Reference position drawing

Adjust arm 1 or 2 to a
position within ± 1
graduation of the center.

Positioning
mark label for
arm 2

Positioning mark
label for arm 1

Positioning mark
label for arm 1

Arm 1

Arm 2

z Always press the emergency-stop switch before setting an adjustment jig. Failure to do so may

cause the robot to malfunction and result in a serious accident.

Warning

Advertising