3. PCON-CA/CF

A


118


(* In the table, ON indicates that the applicable bit is “1,” while OFF indicates that the bit is “0.”)

Signal type

Bits

Symbol

Description

Details

Current

position

32-bit data

-

32-bit signed integer indicating the current position.
The setting unit is 0.01 mm.
(Example) Reading: 000003FF

H

= 1023 (decimal)

= 10.23 mm

* If current positions are read as hexadecimals, negative values

are indicated by 2’s complements.

3.9 (3)

Command

current

32-bit data

-

32-bit integer.
The electrical current presently specified by a command is
indicated.
The setting unit is mA.
(Example) Reading: 000003FF

H

= 1023 (decimal)

= 1023 mA

3.9 (3)

Current

speed

32-bit data

-

32-bit integer.
The current speed is indicated.
The setting unit is 0.01 mm/sec.
(Example) Reading: 000003FF

H

= 1023 (decimal)

= 10.23 mm/sec

3.9 (3)

Alarm

code

16-bit data

-

16-bit integer.
If an alarm occurred, a corresponding alarm code is output.
If no alarm is present, “0” is set.
For details on alarms, refer to the operation manual for the
controller.

3.9 (3)

Total moving

count

32-bits

data

-

32-bit integer
(unit: times)

-

Total moving

distance

32-bits

data

-

32-bit integer
(unit: m)

-

b15

b14

b13

b12

b11

b10

b9

b8

b7

b6

b5

b4

b3

b2

b1

-

Unavailable

-

PLC in

put

Status

Signal 1

b0 ALML

Light error status:
Turns ON when light alarm (threshold exceeded for number of
movement, etc.) that the operation can be continued with is
issued.
Note: ALM LED would not turn ON with a light error.

3.7.7 (31)