IAI America PCON-CFA User Manual

Page 30

Advertising
background image

2. ACON-C/CG,

PCON-C/CG


24




Setting of Parameter No. 25

Positioning mode (standard)

Teaching mode

(teaching type)

256-point mode
(256-point type)

0 1 2

Category

Port

No.

Symbol

Signal name

Symbol

Signal name

Symbol

Signal name

0

PC1 PC1 PC1

1

PC2 PC2 PC2

2

PC4 PC4 PC4

3

PC8 PC8 PC8

4

PC16 PC16 PC16

5 PC32

Command position

number

PC32

Command position

number

PC32

6 -

MODE

Teaching mode

command (operation

mode)

PC64

7 -

JISL

Jog/inch

switching

PC128

Command position

number

8 -

Not available.

JOG+ +Jog

-

Not

available.

9 BKRL

Forced brake

release

JOG- -Jog BKRL

Forced brake

release

10 RMOD Operation

mode RMOD

Operation mode

RMOD

Operation mode

11

HOME

Home return

HOME

Home return

HOME

Home return

12

*STP Pause *STP Pause *STP Pause

13 CSTR Positioning

start

CSTR/
PWRT

Positioning

start/position-data

read command

CSTR Positioning

start

14

RES Reset RES Reset RES Reset

PLC
output

o

PCON
input

15

SON

Servo ON command

SON

Servo ON command

SON

Servo ON command

0 PM1

PM1

PM1

1 PM2

PM2

PM2

2 PM4

PM4

PM4

3 PM8

PM8

PM8

4

PM16 PM16 PM16

5 PM32

Completed position

number

PM32

Completed position

number

PM32

6 MOVE Moving

signal MOVE

Moving signal

PM64

7 ZONE1

Zone

1

MODES

Teaching mode

signal

PM128

Completed position

number

8 PZONE Position

zone PZONE

Position

zone PZONE Position

zone

9 RMDS

Operation mode

status

RMDS

Operation mode

status

RMDS

Operation mode

status

10 HEND

Home return

complete

HEND

Home return

complete

HEND

Home return

complete

11 PEND

Position complete

signal

PEND/
WEND

Position complete

signal/position-data

read complete

PEND

Position complete

signal

12

SV Ready SV Ready SV Ready

13 *EMGS Emergency

stop *EMGS

Emergency stop

*EMGS

Emergency stop

14

*ALM Alarm *ALM Alarm *ALM Alarm

PCON
output

o

PLC input

15

LOAD/

TRQS

Load output

judgment/torque

level

- Not

available.

LOAD/

TRQS

Load output

judgment/torque

level

The signals indicated by * are ON in a normal state.
The signals denoted by “Not available” are not controlled (their ON/OFF status is indeterminable).

PCON

Advertising
This manual is related to the following products: