IAI America PCON-CFA User Manual

Page 178

Advertising
background image

4. SCON-CA


172

Setting of Parameter No. 25

512-point mode

Solenoid mode 1

Solenoid mode 2

3 4 5

Category

Port

No.

Symbol

Signal name

Symbol

Signal name

Symbol

Signal name

0

PC1

ST0

Start position 0

ST0

Start position 0

1

PC2

ST1

Start position 1

ST1

Start position 1

2

PC4

ST2

Start position 2

ST2

Start position 2

3 PC8

ST3 Start

position

3 -

4 PC16

ST4 Start

position

4

-

5 PC32

ST5 Start

position

5

-

6 PC64

ST6 Start

position

6

-

7 PC128

-

-

8 PC256

Command position

number

-

Not available.

-

Not available.

9 BKRL

Forced brake

release

BKRT

Forced brake

release

BKRL

Forced brake release

10 RMOD Operation

mode RMOD

Operation mode

RMOD

Operation mode

11

HOME

Home return

HOME

Home return

-

12 *STP

Pause

*STP

Pause

-

13

CSTR

Positioning start

-

Not available.

-

Not available.

14 RES

Reset

RES

Reset

RES

Reset

PLC
output

o

SCON-CA
input

15

SON

Servo ON command

SON

Servo ON command

SON

Servo ON command

0

PM1

PE0

Position 0 complete

LS0

Rear end move

command 0

1

PM2

PE1

Position 1 complete

LS1

Rear end move

command 1

2

PM4

PE2

Position 2 complete

LS2

Rear end move

command 2

3

PM8

PE3

Position 3 complete

-

4

PM16

PE4

Position 4 complete

-

5

PM32

PE5

Position 5 complete

-

6

PM64

PE6

Position 6 complete

-

Not available.

7

PM128

ZONE1

Zone 1

ZONE1

Zone 1

8 PM256

Completed position

number

PZONE

ZONE2

Position zone/

Zone 2

PZONE

ZONE2

Position zone/

Zone 2

9 RMDS

Operation mode

status

RMDS

Operation mode

status

RMDS

Operation mode

status

10 HEND

Home return

complete

HEND

Home return

complete

HEND

Home return

complete

11 PEND

Position complete

signal

PEND

Position complete

signal

-

Position complete

signal

12 SV

Ready

SV

Ready

SV

Ready

13 *EMGS Emergency

stop *EMGS

Emergency stop

*EMGS

Emergency stop

14 *ALM

Alarm

*ALM

Alarm

*ALM

Alarm

SCON-CA
output

o

PLC input

15 *BALM

Battery alarm

.

*BALM

Battery alarm

.

*BALM

Battery alarm

.

The signals indicated by * are ON in a normal state.
The signals denoted by “Not available” are not controlled (their ON/OFF status is indeterminable).

Advertising
This manual is related to the following products: