4. Description of Operating Functions

• Rod type

(1) RA2C type

(2) RA3C type

Current-limiting value (ratio, %)

Low-speed type

(Lead: 2.5 mm)

Current-limiting value (ratio, %)

Medium-speed type

(Lead: 5 mm)

Current-limiting value (ratio, %)

Caution: Precision of each push force at standstill is not guaranteed, and the above are reference

values only.
Exercise caution that if the push force is too small, the actuator may malfunction during
push-motion operation due to slide resistance, etc.
Find the maximum current-limiting value of your controller from the applicable graph above.
The minimum value is 20%

Push force

(N)

Push force

(N)

Push force

(N)