DeviceNet Gateway


[Alarm Description List]
The list below shows the alarm descriptions to be output by PM8 to PM1 (as a binary code) while the
corresponding alarms are present. For details of alarm descriptions, refer to the operation manual for the
controller.

: ON X: OFF

ALM PM8 PM4 PM2 PM1

Output

code

Description *2

Remarks

X - - - - -

Normal

X X X

1

Used by the manufacturer

*1

X X

X

2

Used by the manufacturer

*1

X X

3

Movement command at servo OFF (80)
Position command before completion of
home return (82)
Absolute position movement command
before completion of home return (83)
Movement command during home return
(84)

X

X

X

4

PCB mismatch error (F4)

X

X

5

Non-volatile memory write error (F7)

*1

X

X 6

Parameter data error (A1)
Position data error (A2)
Position command information data error
(A3)

X

7

Excitation detection error (B8)
Operation timeout during home return
operation (BE)

X

X

X

8

Excessive actual speed (C0)

X X

9

Overvoltage (C9)
Overheat (CA)
Control power-supply voltage error (CC)
Control power-supply voltage low (CE)

X

X

A

Used by the manufacturer

*1

X

B

Position deviation counter overflow (D8)

X

X

C

Servo error (C1)

X

D

Open phase A, B (E8)
Open phase A (E9)
Open phase B (EA)
RCP2 absolute encoder error detection 1
(ED)
RCP2 absolute encoder error detection 2
(EE)
RCP2 absolute encoder error detection 3
(EF)

X E

CPU error (FA)
FPGA error (FB)

F

Non-volatile memory rewrite life exceeded
(F5)
Non-volatile memory write timeout (F6)
Non-volatile memory data corrupted (F7)

*1 These errors will not occur while the gateway unit is in use.