LevelOne FGP-2472 User Manual

Page 19

Advertising
background image

13

Gigabit Fiber with BiDi-SC 1550nm SFP module

The following table lists the types of fiber that we support and those else not

listed here are available upon request.

IEEE 802.3z
Gigabit Ethernet
1000SX 850nm

Multi-mode Fiber Cable and Modal Bandwidth

Multi-mode 62.5/125

µ

m

Multi-mode 50/125

µ

m

Modal

Bandwidth

Distance

Modal
Bandwidth

Distance

160MHz-Km

220m

400MHz-Km

500m

200MHz-Km

275m

500MHz-Km

550m

1000Base-
LX/LHX/XD/ZX

SFP.0LC.212.10/30/50/70/B0 Km

Single-mode Fiber 9/125

µ

m

Single-mode transceiver 1310nm 10Km

Single-mode transceiver 1550nm 30, 50, 70, 110Km

1000Base-LX
Single Fiber
WDM Module

SFP.0BL.621.202

Single-Mode

*20Km

TX(Transmit) 1310nm

RX(Receive) 1550nm

SFP.0BL.621.201

Single-Mode

*20Km

TX(Transmit) 1550nm

RX(Receive) 1310nm


Table2-1

2-1-3-3. Switch Cascading in Topology

Takes the Delay Time into Account

Theoretically, the switch partitions the collision domain for each port in switch

cascading that you may up-link the switches unlimitedly. In practice, the network
extension (cascading levels & overall diameter) must follow the constraint of the
IEEE 802.3/802.3u/802.3z and other 802.1 series protocol specifications, in which
the limitations are the timing requirement from physical signals defined by 802.3
series specification of Media Access Control (MAC) and PHY, and timer from some
OSI layer 2 protocols such as 802.1d, 802.1q, LACP and so on.

The fiber, TP cables and devices’ bit-time delay (round trip) are as follows:

1000Base-X TP, Fiber

100Base-TX TP

100Base-FX Fiber

Round trip Delay: 4096

Round trip Delay: 512

Cat. 5 TP Wire:

11.12/m

Cat. 5 TP Wire: 1.12/m

Fiber Cable:

1.0/m

Fiber Cable :

10.10/m

TP to fiber Converter: 56

Bit Time unit : 1ns (1sec./1000 Mega bit) Bit Time unit: 0.01

µ

s (1sec./100 Mega bit)

Table 2-2

Sum up all elements’ bit-time delay and the overall bit-time delay of

wires/devices must be within Round Trip Delay (bit times) in a half-duplex network
segment (collision domain). For full-duplex operation, this will not be applied. You
may use the TP-Fiber module to extend the TP node distance over fiber optic and
provide the long haul connection.