2-1-4. Configuring the Management Agent of

We offer you three ways to startup the

are RS-232 console, CLI, and Web. Users can use any one
configure the switch. You can touch them through the following procedures.

Section 2-1-4-1: Configuring the Management Agent of

Serial RS-232 Port

Section 2-1-4-2: Configuring the Management Agent of

Ethernet Port

Note: Please first modify the IP address, Subnet mask

DNS through RS-232 console, and then

2-1-4-1. Configuring the Management Agent

RS-232 Port

To perform the configuration through RS

port must be directly connected to a DCE device, for example, a PC, through
RS-232 cable with DB-9 connector. Next, run a termina
setting of the switch’s serial port. With this, you can communicate with the switch.

In the switch, RS-232 interface only supports baud rate 57.6k bps with 8 data

bits, 1 stop bit, no parity check and no flow control.










To configure the switch, please

1.

Find the RS-232 DB-9 cable with female DB
Normally, it just uses pins 2, 3 and 7. See also Appendix B for more
details on Null Modem Cable Specifications.

2.

Attaches the DB-9 female cable connector to the male serial RS
DB-9 connector on the switch.

3.

Attaches the other end of the serial RS
port, running a terminal emulator supporting VT100/ANSI terminal with
The switch’s serial port default settings. For example,
Windows98/2000/XP HyperTerminal utility.


Note: The switch’s serial port default settings are listed as follows:

Terminal or Terminal Emulator

RS-232 cable with female
DB-9 connector at both ends

RS-232

RS-232 DB-9 Connector

16

Configuring the Management Agent of FGP-2472

three ways to startup the switch management function. They

sers can use any one of them to monitor and

ou can touch them through the following procedures.

the Management Agent of FGP-2472 through the

the Management Agent of FGP-2472 through the

lease first modify the IP address, Subnet mask, Default gateway and

and then do the next.

the Management Agent of FGP-2472 through the Serial

To perform the configuration through RS-232 console port, the switch’s serial

port must be directly connected to a DCE device, for example, a PC, through

. Next, run a terminal emulator with the default

setting of the switch’s serial port. With this, you can communicate with the switch.

232 interface only supports baud rate 57.6k bps with 8 data

bits, 1 stop bit, no parity check and no flow control.

, please follow the procedures below:

9 cable with female DB-9 connector bundled.

Normally, it just uses pins 2, 3 and 7. See also Appendix B for more
details on Null Modem Cable Specifications.

9 female cable connector to the male serial RS-232

9 connector on the switch.

Attaches the other end of the serial RS-232 DB-9 cable to PC’s serial
port, running a terminal emulator supporting VT100/ANSI terminal with

rt default settings. For example,

Windows98/2000/XP HyperTerminal utility.

Note: The switch’s serial port default settings are listed as follows:

FGP-2472
Default IP Setting:
IP address = 192.168.1.1
Subnet Mask = 255.255.255.0
Default Gateway = 192.168.1.254

Fig. 2-7

232 cable with female
9 connector at both ends

AC Line 100-240V 50/60 Hz