Alarms for Power Failure

Step 1: There are two pins on the terminal block used for power failure detection. It

provides the normally closed output when the power source is active. Use this as a
dry contact application to send a signal for power failure detection.

Term

inal Bl

ock

PW1

+

12 48VDC

Power Ground

PW2

+

12 48VDC

Power Ground

Earth Ground

Relay Output

1A @ 24VDC

Relay Alarm warning signal disable for following:
3. The relay contact closes if Power1 and Power2 are both failed but Power3 on
4. The relay contact closes if Power3 is failed but Power1 and Power2 are both on

DC

Jack

PW3

DC Jack

12VDC




Special note:
The relay output is normal open position when there is no power to the switch.
Please do not connect any power source to this terminal to prevent shorting your
power supply.