7 ianalyzer::stoprecording, Ianalyzer::stoprecording – Teledyne LeCroy FireInspector Automation Application Programming Interface User Manual
Page 20

16
FireInspector Automation User’s Manual
CATC
Version 1.0
2.3.7
IAnalyzer::StopRecording
Stops recording started by
StartRecording
method.
Syntax
HRESULT StopRecording (
[in] BOOL abort_upload );
Parameters
•
abort_upload
–
TRUE
, if caller wants to abort upload, no trace file will be created,
FALSE
if want to upload recorded trace
Return values
•
ANALYZERCOMERROR_EVENTSINKNOTINSTANTIATED
–
event sink was not
instantiated
•
ANALYZERCOMERROR_UNABLESTOPRECORDING
–
error stopping recording
Remarks
Stops recording started by
'
StartRecording
'
method. The event will be issued when
recording is actually stopped (via
_IAnalyzerEvents
interface), if the parameter of
method call was FALSE.
Example
VBScript:
<OBJECT
RUNAT=Server
ID = Analyzer
CLASSID = "clsid:0B179BC1-DC61-11D4-9B71-000102566088"
>
</OBJECT>
<SCRIPT LANGUAGE="VBScript">
<!--
Sub BtnStopRecording_OnClick
On Error Resume Next
Analyzer.StopRecording True
If Err.Number <> 0 Then
MsgBox Err.Number & ":" & Err.Description
End If
End Sub
-->
</SCRIPT>
C++:
IFwAnalyzer* fw_analyzer;
. . .
try
{
fw_analyzer->StopRecording( FALSE )
}
catch ( _com_error& er)