7 ianalyzer::stoprecording, Ianalyzer::stoprecording – Teledyne LeCroy FireInspector Automation Application Programming Interface User Manual

Page 20

Advertising
background image

16

FireInspector Automation User’s Manual

CATC

Version 1.0

2.3.7

IAnalyzer::StopRecording

Stops recording started by

StartRecording

method.

Syntax

HRESULT StopRecording (

[in] BOOL abort_upload );

Parameters

abort_upload

TRUE

, if caller wants to abort upload, no trace file will be created,

FALSE

if want to upload recorded trace

Return values

ANALYZERCOMERROR_EVENTSINKNOTINSTANTIATED

event sink was not

instantiated

ANALYZERCOMERROR_UNABLESTOPRECORDING

error stopping recording

Remarks
Stops recording started by

'

StartRecording

'

method. The event will be issued when

recording is actually stopped (via

_IAnalyzerEvents

interface), if the parameter of

method call was FALSE.

Example

VBScript:

<OBJECT

RUNAT=Server

ID = Analyzer

CLASSID = "clsid:0B179BC1-DC61-11D4-9B71-000102566088"

>

</OBJECT>

<SCRIPT LANGUAGE="VBScript">

<!--

Sub BtnStopRecording_OnClick

On Error Resume Next

Analyzer.StopRecording True

If Err.Number <> 0 Then

MsgBox Err.Number & ":" & Err.Description

End If

End Sub

-->

</SCRIPT>

C++:

IFwAnalyzer* fw_analyzer;

. . .

try

{

fw_analyzer->StopRecording( FALSE )

}

catch ( _com_error& er)