IRecOptions::SetSaveExternalSignals
Sets the flag indicating to save external signals.
Syntax
HRESULT SetSaveExternalSignals (
[in] BOOL save );
Parameters
•
save
– possible values:
•
TRUE
– save external signals
•
FALSE
– do not save external signals
Return values
Remarks
By default external signals are not saved.
Example
WSH:
CurrentDir = Left(WScript.ScriptFullName,
InstrRev(WScript.ScriptFullName, "\"))
Set Analyzer = WScript.CreateObject("CATC.FwAnalyzer")
Set RecOptions = Analyzer.GetRecordingOptions
RecOptions.SetSaveExternalSignals TRUE
C++: