50

FireInspector Automation User’s Manual

CATC

Version 1.0

2.5.1

IRecOptions::Load

Loads recording options from specified file.

Syntax

HRESULT Load (

[in] BSTR ro_file_name );

Parameters

ro_file_name

string providing the full pathname to the recording options file

Return values

ANALYZERCOMERROR_UNABLEOPENFILE

unable to open file

Remarks

Example

WSH:

CurrentDir = Left(WScript.ScriptFullName,

InstrRev(WScript.ScriptFullName, "\"))

Set Analyzer = WScript.CreateObject("CATC.FwAnalyzer")

Set RecOptions = Analyzer.GetRecordingOptions

RecOptions.Load( CurrentDir & "Input\rec_options.rec" )

C++: