Packet with Bad ICRC
TD_10.2.4.1.2
TD_10.3.1.1.2
Item
Value
Name
TD_10.2.4.1.2
Description
The test is used to ensure that the DUT does not re-
spond to a packet with an invalid ICRC.
Topology
Simple
Initial link state
Active
Assertions
v1c07-007#01.02
DUT
Channel Adapter
Prerequisites
SanityCheck
The generator property ‘BADPacketDiscard’ is set to
zero.
Test procedure
A SubnDirectGet(PortInfo) SMP with a bad ICRC is
sent to the DUT. No response is expected.
Item
Value
Name
TD_10.3.1.1.2
Description
The test is used to ensure that the DUT does not re-
spond to a packet with invalid ICRC.
Topology
Simple
Initial link state
Active
Assertions
v1c07-009#01.02
DUT
Switch; Router
Prerequisites
SanityCheck
The generator property ‘BADPacketDiscard’ is set to
zero.
Test procedure
A SubnDirectGet(PortInfo) SMP with an invalid ICRC
is sent to the DUT. No response is expected.