Packet with bad lver – Teledyne LeCroy IBTrainer - IBTrainer Users Manual User Manual
Page 84

Using the InfiniBand Compliance Test Suite
Test Description
84
CATC IBTrainer InfiniBand Exerciser, August 2002
Packet with Bad LVer
TD_10.2.4.1.3
TD_10.3.1.1.3
Item
Value
Name
TD_10.2.4.1.3
Description
The test is used to ensure that the DUT does not re-
spond to a packet with invalid settings in the LRH
field ‘LVer’.
Topology
Simple
Initial link state
Active
Assertions
v1c07-007#01.03
DUT
Channel Adapter
Prerequisites
SanityCheck
Test procedure
Sending SubnDirectGet(PortInfo) SMPs to the DUT
with the 'LVer'-field in the LRH set to the invalid
values 1-15. No response expected.
Item
Value
Name
TD_10.3.1.1.3
Description
The test is used to ensure that the DUT does not re-
spond to a packet with invalid settings in the LRH
field ‘LVer’.
Topology
Simple
Initial link state
Active
Assertions
v1c07-009#01.03
DUT
Switch, Router
Prerequisites
SanityCheck
Test procedure
Sending SubnDirectGet(PortInfo) SMPs to the DUT
with the 'LVer'-field in the LRH set to the invalid
values 1-15. No response expected.