Using the InfiniBand Compliance Test Suite

Test Description

82

CATC IBTrainer InfiniBand Exerciser, August 2002

Packet Receive Statemachine BAD PKT

TD_10.2.4.1.9

Item

Value

Name

TD_10.2.4.1.9

Description

The test is used to ensure that the DUT does not re-
spond to a packet where the ‘EGP’ of this packet is re-
placed by an invalid code group, ‘SLP’, and ‘SDP’.

Topology

Simple

Initial link state

Active

Assertions

v1c07-007#02.01 v1c07-007#02.02

DUT

Channel Adapter

Prerequisites

SanityCheck

Test procedure

1 A SubnDirectGet(PortInfo) packet is sent out, but

with an invalid code group instead of 'EGP' (End of

Good Packet). No response is expected.

2 A SubnDirectGet(PortInfo) packet is sent out, but

with 'SLP' (Start of Link Packet) instead of 'EGP' (End

of Good Packet). No response is expected.

3 A SubnDirectGet(PortInfo) packet is sent out, but

with 'SDP' (Start of Data Packet) instead of 'EGP'

(End of Good Packet). No response is expected.