Packet receive statemachine bad pkt – Teledyne LeCroy IBTrainer - IBTrainer Users Manual User Manual
Page 82

Using the InfiniBand Compliance Test Suite
Test Description
82
CATC IBTrainer InfiniBand Exerciser, August 2002
Packet Receive Statemachine BAD PKT
TD_10.2.4.1.9
Item
Value
Name
TD_10.2.4.1.9
Description
The test is used to ensure that the DUT does not re-
spond to a packet where the ‘EGP’ of this packet is re-
placed by an invalid code group, ‘SLP’, and ‘SDP’.
Topology
Simple
Initial link state
Active
Assertions
v1c07-007#02.01 v1c07-007#02.02
DUT
Channel Adapter
Prerequisites
SanityCheck
Test procedure
1 A SubnDirectGet(PortInfo) packet is sent out, but
with an invalid code group instead of 'EGP' (End of
Good Packet). No response is expected.
2 A SubnDirectGet(PortInfo) packet is sent out, but
with 'SLP' (Start of Link Packet) instead of 'EGP' (End
of Good Packet). No response is expected.
3 A SubnDirectGet(PortInfo) packet is sent out, but
with 'SDP' (Start of Data Packet) instead of 'EGP'
(End of Good Packet). No response is expected.