Teledyne LeCroy UWBTracer User Manual User Manual
Page 203

UWBTracer/Trainer User Manual
Chapter 12: Recording Options
LeCroy Corporation
185
Scan Time per Channel
Set the scan period for each channel. The range is 0 to 64,000 milliseconds. The default
is 1000 milliseconds. You can set this option only when the Channel Sync Mode is set to
"Scan Channels."
Loss-of-Sync Timeout
Set the timeout period to use when out-of-synchronization occurs. The range is
0 to 64,000 milliseconds. The default is 10,000 milliseconds.
Force Resynchronization
Resynchronizes the analyzer receiver PHY with the signal from the devices under test.
If the RF channel is already synchronized to transmitted data from a DUT, this setting
forces the analyzer to terminate the synchronization and then try to resynchronize when
a new recording begins.
Note: If the analyzer is in "Scan Channels" Channel Sync Mode and you modify the
channel setting, the software sets the Force Resynchronization flag
internally.