15 oven gas requirements – XLT XD-9004E User Manual

Page 15

Advertising
background image

Technical Support US: 888-443-2751

Technical Support INTL: 316-943-2751

15

OVEN GAS REQUIREMENTS

Gas Group

I

2H

I

2E

I

2E+

I

2L

I

3+

I

3B/P (30)

I

3P (30/37/50)

I

3B (37)

Inlet pressure (mbar)

20

20 20/25 25 28/30/37/50 28-30/37/50

30/37/50

37

Number of injectors
Main burner opening size
Ignition
Inlet connection

Fixed
Electric Direct Spark Igniter
BSP 3/4" male thread

World Oven Gas Group

(1) per burner

Natural Gas

Propane Gas

I

2H

I

2L

I

2E

I

2E+

I

3B/P

I

3+

I

3P

Austria

AT

X

X

Belgium

BE

X

X

Cyprus

CY

X

X

X

Czech Republic

CZ

X

X

Denmark

DK

X

X

Estonia

EE

X

Finland

FI

X

X

France

FR

X

X

X

X

Germany

DE

X

X

X

Greece

GR

X

Hungary

HU

X

X

Iceland

IS

Ireland

IE

X

X

X

Italy

IT

X

X

Latvia

LT

X

Lithuania

LV

Luxembourg

LU

Malta

MT

X

X

Netherlands

NL

X

X

X

Norway

NO

X

Poland

PL

X

Portugal

PT

X

X

X

Slovakia

SK

X

Slovenia

SI

X

Spain

ES

X

X

X

Sweden

SE

X

X

Switzerland

CH

X

X

X

X

United Kingdom

GB

X

X

X

Natural Gas (8.75 mbar manifold)

Country

Symbol

Gas Matrix by Country

LP Gas (25 mbar manifold)

Advertising