OVEN ELECTRICAL REQUIREMENTS

FOR EACH OVEN:

A separate 20A circuit breaker must be provided for each oven deck.

Electrical connections must be accessible when the ovens are in the installed position.

Electrical connections must meet all local code requirements.

All values shown this page are per each oven

When installed, the appliance must be electrically grounded in accordance with
local codes, or in the absence of local codes, with the National Electrical Code,
ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.2, as applicable.

This appliance is equipped with a three-prong (grounding) plug for your protec-
tion against shock hazard & should be plugged into a properly grounded three-
prong receptacle. Do not cut or remove the grounding prong from this plug

.

Electrical Grounding Instructions

World Ovens

This appliance is equipped with a ground lug for your protection against shock
hazard & must be properly grounded.

When installed, the appliance must be electrically grounded in accordance with
local codes.

Australian Ovens

This appliance is equipped with a ground lug for your protection against shock
hazard & must be properly grounded.

The electrical service must be installed in accordance with AS/NZS 3000 Wir-
ing Rules.

Standard Ovens

HIGH

VOLTAGE

Volts AC Amps Hertz Volts AC Amps Hertz Volts AC Watts Hertz

1832

6

3

1855

6

3

2440

6

3

3240

6

3

3255

6

3

3270

6

3

3270-2B

12

6

1320

3855

6

3

3870

6

3

3870-2B

12

6

1320

50

120 VAC

60

220/230/

240 VAC

220 VAC

660

660

Oven

Model

Australia & World

Standard

Gas Oven Electrical Requirements

Per EACH Oven

Korea

60

Advertising