OVEN TROUBLESHOOTING

Verify that the power cord to the oven is connected and/or plugged in if equipped with a plug
and receptacle.

Check to see that the circuit breakers in the building electrical service panel have not been
tripped or turned off.

Check all circuit breakers on the oven control panel to ensure they have not been tripped.

Gas line size and pressure must be adequate to support total BTU requirements with all appli-
ances in store turned on. Refer to the “Oven Gas Requirements” section of this manual.

Check the quick-disconnect on the gas hose to verify that it is fully and completely engaged.

Check the manual gas valve to verify that it is turned on completely. The handle on the valve
should be parallel with the gas piping when the valve is turned on, and the handle will be per-
pendicular with the gas piping when the valve is turned off. Also remember that anytime the
gas hose has been disconnected it will take time to purge the air from the gas train.

Check to see that the oven is fully assembled. All of the fingers must be properly installed.
Incorrect or incomplete finger placement can cause a “windy” condition that can cause the
burner not to light.

If your oven does not function properly, please verify the following conditions:

If your oven still does not function properly, XLT has qualified customer service personnel

that can provide assistance on any type of XLT oven problem you may experience. Customer Ser-