TANK-700 Embedded System

Page 46

3.11.2.2 Switch to Backup Power

During operation, system power switches from Power 2 to Power 1 automatically when the

following situations occur:

ƒ

Power 2 < 10.5V and Power 1 > 9V

ƒ

Power 2 is unplugged and Power 1 > 9V

The following flow diagram shows how the power is switched between Power 2 and

Power 1 and their LED statuses.

Figure 3-42: ACC Off: Switch Between PWR1 and PWR2

NOTE:

System power can switch between Power 2 and Power 1 automatically

when

a 12 V power adapter is being connected to Power 2 and the

power input of Power 1 is from 9 V to 16 V. If Power 2 is unplugged and

the power input of Power 1 is over 16 V, system power will switch to

Power 1 automatically. However, the system remains using the power

source from Power 1 even if Power 2 is re-plugged.

System power can switch between Power 2 and Power 1 automatically

when

a 19 V power adapter is being connected to Power 2 and the

power input of Power 1 is from 9 V to 26 V. If Power 2 is unplugged and

the power input of Power 1 is over 26 V, system power will switch to

Power 1 automatically. However, the system remains using the power

source from Power 1 even if Power 2 is re-plugged.