Installation, Vent requirements, For qualified installers only) – Avalon Stoves Freestanding Stove User Manual

Page 11

Advertising
background image

Installation

(for qualified installers only)

1 1

Travis Industries

9 3 5 0 8 1 1 5

4 0 5 0 1 1 3

Vent Requirements

!

Always maintain the required 1” clearance (air space) to combustible materials to prevent a fire hazard.
Do not fill air spaces with insulation.

!

The gas appliance and vent system must be vented directly to the outside of the building, and never
be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas
appliance must use it’s own separate vent system.

This appliance is equipped only for
altitudes 0-2000 feet. However,
our in-house testing has shown
that the unit operated at altitudes to
8000 ft.

!

Failure to adjust the air shutter
properly may lead to improper
combustion which can create a
safety hazard. Consult your dealer
or installer if you suspect an
improperly adjusted air shutter.

When the vent passes through a
wall, a wall thimble is required.
When the vent passes through a
ceiling, a support box or firestop is
required. When the vent passes
through the roof, a roof flashing
and storm collar are required.
Follow the instructions provided
with the vent for installing these
items.

Use a firestop spacer whenever
passing through a ceiling

Vertical Termination NOTE: always
use the "high-wind" version (if
applicable)

Use a roof flashing and storm collar
whenever passing through the roof

Use a support box
on exposed vent

Vertical Vent

Requirements

Use a firestop whenever
passing through a wall

Horizontal Termination

Maintain a minimum 1"
clearance from vent to any
combustible.

Minimum
Framing for
wall thimble

Horizontal Vent

Requirements

Minimum framing
for fire stop

Maintain a minimum 1"
clearance from vent to
any combustible

8-5/8"

8-5/8"

Use of of the following 6-5/8" diameter co-axial gas direct vent systems:

Manuafacturer

S e r i e s

Simpson Dura-Vent

Model GS

Selkirk Hearth Products

Direct-Temp

American Metal Products

Ameri-Vent

N O T E

: Always use the high-wind cap for the type of vent you are using (if applicable)

Slide the vent sections together and turn 1/4 turn until the sections lock in place.

Screws are not required to secure the vent. However, three screws may be used to
secure vent sections together if desired.

High temperature sealant is recommended at the appliance starter section connection
(use high-temperature silicone or Mill-Pac®).

If disassembly is required, at time of re-assembly check to see if the vent creates a tight
fit. If it does not, apply high temperature sealant to the joints of the affected sections.

Horizontal sections require a 1/4" rise every 12" of travel

Horizontal sections require non-combustible support every three feet (e.g.: plumbing
tape)