Installation – Avalon Stoves Freestanding Stove User Manual

Page 18

Advertising
background image

18

Installation

(for qualified installers only)

Travis Industries

9 3 5 0 8 1 1 5

4 0 5 0 1 1 3

Approved Venting Configurations for Vertical Terminations with
Three 90° Elbows

(Two 90° Vertical and One 45° or 90° Horizontal Elbow)

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position.

5 feet

10' (min)

15 feet

20 feet

25 feet

30 feet

0 feet

40' (max)

5 feet

0 feet

0 feet

5 feet

10' (min)

15 feet

20 feet

25 feet

30 feet

40' (max)

Restrictor

Position # 5

NOTE:

Restrictor positions are based

upon lab tests. The ideal

restrictor position may vary

slightly, especially when the

termination is near a demarkation

line.

10 feet

15 feet

20 feet

24 ' (max)

0 feet

5 feet

10 feet

15 feet

20 feet

24 ' (max)

35 feet

35 feet

Restrictor

Position # 1

NOTE:

Horizontal sections require a

1/4" rise every 12" of travel.

This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 45° or 90° elbow.

This is considered a
vertical elbow

Horizontal length (max. 24') is calculated
by adding both lengths of horizontal run
(Horizontal Length = H1 + H2).

H1

H2

This is considered a
vertical elbow