Installation – Avalon Stoves Freestanding Stove User Manual

Page 15

Advertising
background image

Installation

(for qualified installers only)

1 5

Travis Industries

9 3 5 0 8 1 1 5

4 0 5 0 1 1 3

Approved Venting Configurations with a Horizontal Termination
and Two Elbows (

one 90° vertical and one 90° or 45° horizontal elbow

)

•

If using a Snorkel Termination (14” or 36”) add the snorkel height to the vertical height (snorkel
terminations are used primarily for basement installations).

•

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position.

5 feet

10' (min)

15 feet

19' (max)

0 feet

5 feet

0 feet

0 feet

5 feet

10' (min)

15 feet

Restrictor

Position # 5

NOTE:
Restrictor positions are based upon lab
tests. The ideal restrictor position may vary
slightly, especially when the termination is
near a demarkation line.

Restrictor

Position # 1

10 feet

15 feet

20 feet

24 ' (max)

0 feet

5 feet

10 feet

15 feet

20 feet

24 ' (max)

19' (max)

NOTE:
Horizontal sections require a 1/4"
rise every 12" of travel.

This is considered a horizontal
elbow (it does not matter
whether it turns right or left).
It may be a 90° or 45° elbow.

This is considered a
vertical elbows

Horizontal length (max. 24') is calculated
by adding both lengths of horizontal run
(Horizontal Length = H1 + H2).

H1

H2

NATURAL GAS: Min. 2' Section Required

PROPANE (LP): Min. 3' Section Required