Installation addenda, Addendum #1 class a chimney conversion kit, Addendum #2 interior masonry chimney conversions – Avalon Stoves Freestanding Stove User Manual

Page 41

Advertising
background image

Installation Addenda

4 1

Travis Industries

9 3 5 0 8 1 1 5

4 0 5 0 1 1 3

ADDENDUM #1 Class A Chimney Conversion Kit

Simpson Duravent provides a conversion kit for those wishing to use an existing wood stove chimney to vent
this direct vent stove. The illustration below gives an overview of this type of installation. See the instructions
included with the kit for details.

!

Do not exceed the maximum vertical rise (see the section "Approved Vent Configurations" starting on page 12)
allowable. Remember to set the restrictor position to the correct position (based upon the vertical rise height).

!

The conversion kit does not work on interior masonry
chimneys.

Chimney Conversion Kit A (# 931)

Metalbestos 6" I.D.
Security Chimneys 6" I.D.
Jackes-Evans 6" I.D.
Hart & Cooley 6" I.D.
Pro-Jet 6" I.D.

Chimney Conversion Kit B (# 932)

Simpson Dura-Vent 6" I.D.
Air-Jet 6" I.D.
Metal-Fab 6" and 7" I.D.
Amer. Metals 6" & 7" I.D.
Metalbestos 7" and 8" I.D.
Jackes-Evans 7" and 8" I.D.
Hart & Cooley 7" and 8" I.D.
Pro-Jet 7" and 8" I.D.
Security Chimneys 8" I.D.

Chimney Conversion Kit C (# 933)

Simpson Dura-Vent 7" and 8" I.D.
American Metals 8" I.D.
Air-Jet 8" I.D.
Metal-Fab 8" I.D.
American Metals 8" I.D.

Each Kit Contains:
Retro Connector
Retro Vertical Top

Additional Required Equipment:
4" Flex (#711 or U.L. 1777)
Termination (#991)
Co-Axial Sections

Type A Chimney

Simpson Duravent Direct

Vent Pipe Sections

(use adjustable section)

Screw the Retro

Vertical Top to the

Flex Pipe

Retro Vertical Top

(screw to chimney)

Screw the Retro

Connector to the

Flex Pipe

Retro Connector

(screw to chimney)

4" (100 mm)

Aluminum Flex

Pipe

Cut the Flex Pipe to

the chimney height

plus 3" (75 mm)

ADDENDUM #2 Interior Masonry Chimney Conversions

Follow the requirements and use the
equipment listed in the illustration to
the right to install this appliance into
an interior masonry chimney.

Maximum vertical rise is 40'

Minimum vertical rise is 10'

See the chart on page 17 for
determining the correct restrictor
position.
NOTE: these restrictor positions are
based upon lab tests. The ideal
restrictor position may vary slightly.

The entire chimney system
must be air-tight. Make sure to
seal the flashing, clean-out,
and thimble connection, and to
inspect the chimney.

#711 Flex Liner
(4” dia.)
(or other UL 1777
Gas Liner)

Co-Axial
Straight
Lengths

#991 High
Wind
Termination

#990 90° Elbow

Flashing
(included in
#934 Masonry
Conversion Kit

Make sure the coaxial pipe
maintains a 1” clearance to any
combustible. The vent must be
sealed air-tight.

High-Temp.

Silicone

Connector with
Cover (included
in #934
Masonry
Conversion Kit