Installation – Avalon Stoves Freestanding Stove User Manual

Page 16

Advertising
background image

16

Installation

(for qualified installers only)

Travis Industries

9 3 5 0 8 1 1 5

4 0 5 0 1 1 3

Approved Venting Configurations with a Horizontal Termination
and Three 90° Elbows (all vertical)

If using a Snorkel Termination (14” or 36”) add the snorkel height to the vertical height (snorkel
terminations are used primarily for basement installations).

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
position.

5 feet

10' (min)

15 feet

21' (max)

0 feet

5 feet

0 feet

0 feet

5 feet

10' (min)

15 feet

Restrictor

Position # 5

NOTE:

Restrictor positions are based
upon lab tests. The ideal restrictor

position may vary slightly,
especially when the termination is

near a demarkation line.

Restrictor

Position # 1

10 feet

15 feet

20 feet

24 ' (max)

0 feet

5 feet

10 feet

15 feet

20 feet

24 ' (max)

21' (max)

NOTE:
Horizontal sections require a 1/4"
rise every 12" of travel.

This is a horizontal elbow -

NOT ALLOWED FOR THIS

VENT CONFIGURATION

These are
vertical elbows.

Advertising