Installation, Approved vent configurations, Restrictor position – Avalon Stoves Freestanding Stove User Manual

Page 12: Measuring vent lengths

Advertising
background image

12

Installation

(for qualified installers only)

Travis Industries

9 3 5 0 8 1 1 5

4 0 5 0 1 1 3

Approved Vent Configurations

Restrictor
Position

A restrictor is built
into the appliance to
control the flow rate
of exhaust gases.
This ensures proper
flames for the wide
variety of vent
configurations.
Depending upon
the vent
configuration, you
may be required to
adjust the restrictor
position. The charts
for approved vent
configurations
describe which
position the vent
restrictor must be in.

Remove the nuts holding
the stove top in place
(see the illustration
below). Lift the stove top
off the stove.

To Adjust the Restrictor

To Access the Restrictor

NOTE:

The restrictor is

shipped in

position #1.

This restrictor is

in position # 6

Lift the cotter pin out.

a

Slide the restrictor

adjustment rod in.

b

Replace the cotter pin

through the correct

hole on the restrictor

adjustment rod.

c

Restrictor

Positions

# 2

# 4

# 6

# 3

# 5

# 1

3/8" Nutdriver

Measuring
Vent Lengths

Vent Horizontal Run

(measure from the closest edge of

the starter section to the end of the

termination)

Vent Height is calculated

to the top of the vent on

horizontal terminations

and to the top of the

termination on vertical

terminations.

Vent

Height

Advertising