SaltDogg LS4 Liquid Spray System User Manual

Installation & operator’s manual, Ls4 liquid spray system, Installation instructions

Advertising
background image

1

TM

9049 Tyler Blvd. • Mentor, Ohio 44060

Phone (440) 974-8888 • Fax (440) 974-0165

Toll-Free Fax 800-841-8003 • saltdogg.com

Installation & Operator’s Manual

LS4 Liquid Spray System

Installation Instructions

1. Position pump enclosure bracket
(#3028485) 4” from rear gusset on driver side
of hopper spreader, (see figs. 1). Make sure
bracket is rested on hopper’s sill.
2. Weld pump enclosure bracket (#3028485)
in place as it shown in fig.1.
3. Position reservoir brackets (#3010977),
gussets (#3011128) and bracket tie downs
(#3011124) as shown in fig.2. Weld all parts in
place as shown in fig.2 and fig.1.
4. Place reservoir (#3010816) on brackets and
secure it using retainer (#3010979) as shown in
fig.3.
5. Use three (#1496505) (see fig. 3) 1-3/4” x 5”
ratchet tie downs to secure reservoir.

6. Plumb: Reservoir, ball valve, filter, pump
enclosure, and spray nozzles according to
plumbing schematic using supplied fittings,
hose, and hose clamps. Do not use Teflon
tape on threads. Use liquid thread sealant.
(see fig. 5, 6, & 7).
7. Two 11/16” diameter holes are predrilled in
the chute guide (#3010180) for installation of
two liquid spray nozzles, see fig.3. Installation
on different brands of spreaders may require
different nozzle locations.

—continued inside