1.3 INTRINSIC SAFETY CONSIDERATIONS

The Model 202A is certified for use in hazardous areas and has both CENELEC
and CSA NRTL/C approvals.

The Model 202A certification details are:

CENELEC Approval:

Kema 98.E.1873.

Type of Protection:

Ex ia.

Group:

IIB.

Temperature Class:

T4 at ambient temperature of 60°C.

CSA NRTL/C Approval
File Number:

LR 104 840-5.

Type:

Class 1, Groups C and D.

When installing in hazardous areas, the instrument will have to be installed
according to the guidelines given in section 6 and in accordance with standards
for wiring and installation in hazardous areas.

4-20mA Input

The input can be connected to IS circuits with the following maximum
values:

Ui = 28V
Ii = 93mA
Pi = 653mW.

Relay Outputs

The outputs can be connected to IS circuits with the following maximum
values:

Ui = 28V
Ii = 93mA
Pi = 653mW.

Introduction 7