Yokogawa 212 Heat Calculator User Manual

Page 45

Advertising
background image

Notes:

FP

This variable is represented in IEEE-754 Floating Point 4 byte
format and requires two 2 byte data registers used as Modicon's
floats:

IEEE-754

Modicon Registers

1st byte

low byte

(register X)

2nd byte

high byte

(register X)

3rd byte

low byte

(register X+1)

4th byte

high byte

(register X+1)

This means that two data registers must be read/written to
obtain/preset one data value.

LI

This variable is represented as a long integer in 4 byte format and
requires two 2 byte data registers:

Long Integer

Modicon Registers

1st byte (MSB)

high byte

(register X)

2nd byte

low byte

(register X)

3rd byte

high byte

(register X+1)

4th byte (LSB)

low byte

(register X+1)

This means that two data registers must be read/written to
obtain/preset one data value.

Communications 43