2. SPECIFICATION
General
Energy Display units:
kWh, MWh, MJ, GJ, therm, BTU x 1000,
tons x hours (refrigeration).
Maximum Thermal
Power:
3000 MW.
Accuracy Class:
OIML R75 Class 4,
EN1434.
Measurement Time:
0.5 sec time interval.
Environmental Class:
EN1434 Classes A & C.
Ambient Temp Range:
0°C to 60°C.
Storage Temp Range:
-20°C to 70°C.
Temperature Measurement
Type of Sensor:
Pt100 to IEC751.
Temperature Range:
-10°C to 220°C
Temperature Difference:
1K to 200K.
Approved Temp Range:
1°C to 200°C.
Approved Temp Difference: 3K to 199K.
Measurement Time:
3 sec time interval.
Display
Type:
LCD with 7 digit numeric display and 11
character display.
Digits:
15.5mm (0.6") high.
Characters:
6mm (0.24") high.
Specification 7