Yokogawa Multi Channel Oxygen Analyzer System ZR22/AV550G User Manual

Page 54

Advertising
background image

<APPENDIX 1. LIST OF PARAMETERS FOR EACH BLOCK OF AV550G>

A-5

IM 11M12D01-61E

TA0102-2.ai

AI3

AUTO

Relative

Index

Index

Parameter Name

Factory Default

Write

Mode

Explanation

AUTO

AUTO

AUTO

AUTO

17

18

19

20
21

22

23

24

25
26

27
28
29
30

31

32

0.0 (AI1)

0.0 (AI2)

0.0 (AI3)

0

0

AUTO

LOW_CUT

PV_FTIME

0sec (AI1)

0sec (AI2)

0sec (AI3)

HI_HI_LIM

FIELD_VAL

UPDATE_EVT

BLOCK_ALM

ALARM_SUM

ACK_OPTION

ALARM_HYS

HI_HI_PRI

HI_PRI
HI_LIM

LO_PRI

LO_LIM

LO_LO_PRI

1. #INF

AUTO

0xffff

0.5%

33

LO_LO_LIM

HI_HI_ALM

AUTO

AI1 AI2

4117

4118

4119

4120

4121

4122

4123

4124

4125
4126

4127
4128
4129
4130

4131

4132

4133

4017

4018

4019

4020
4021

4022

4023

4024

4025
4026

4027
4028
4029
4030

4031

4032

4033

Raw value of the field device in percent of thePV range,

with a status reflecting the Transducer condition, before

signal characterization (L_TYPE), filtering (PV_FTIME), or

low cut (LOW_CUT).

The block alarm is used for all configuration, hardware,

connection failure or system problems in the block. The

cause of the alert is entered in the subcode field. The first

alert to become active will set the Active status in the

Status attribute. As soon as the Unreported status is

cleared by the alert reporting task, another block alert may

be reported without clearing the Active status, if the

subcode has changed.

The current alert status, unacknowledged states,

unreported states, and disabled states of the alarms

associated with the function block.
Selection of whether alarms associated with the block will

be automatically acknowledged.
Amount the PV must return within the alarm limits before

the alarm condition clears. Alarm Hysteresis is expressed

as a percent of the PV span. 0 to 50

Priority of the high high alarm. 0, 1, 3 to 15

Priority of the high alarm. 0, 1, 3 to 15
The setting for high alarm in engineering units. (Note 1)

Priority of the low alarm. 0, 1, 3 to 15
The setting for the low alarm in engineering units.

(Note 2)
Priority of the low low alarm. 0, 1, 3 to 15
The setting of the low low alarm in engineering units.

(Note 2)
The status for high high alarm and its associated time stamp.
The status for high alarm and its associated time stamp.
The status of the low alarm and its associated time stamp.
The status of the low low alarm and its associated time

stamp.

This alert is generated by any change to the static data.

Sets low cut point of output. This low cut value become

available by setting "Low cutoff" to "IO_OPTS".

Time constant of a single exponential filter for the PV, in

seconds.

The setting for high high alarm in engineering units.

(Note 1)

AUTO

0

AUTO

AUTO

34

HI_ALM

4134

4034

35

LO_ALM

4135

4035

36

LO_LO_ALM

4136

4036

1. #INF

-1. #INF

0
-1. #INF

AUTO

Note 1: An intended set value can be written only if Min(OUT_SCALE.EU0, OUT_SCALE.EU100) ≤ the intended value ≤ +INF.

Note 2: An intended set value cannot be written if –INF ≤ the intended value ≤ Min(OUT_SCALE.EU0, OUT_SCALE.EU100).

4217

4218

4219

4220
4221

4222

4223

4224

4225

4226

4227
4228

4229

4230

4231
4232

4233
4234
4235
4236

Advertising