Table 6.3.2 Additional Contents of “DEVICE_STATUS_1”. (Index 1045)

Table 6.4. Error Codes of Errors during Download

Software download is failed.

DOWNLOAD_INCOMPLET

Description

Display through DD

Software download is failed.

0x01000000

Hexadecimal

0x02000000

DOWNLOAD_FAIL

TA0103_2.ai

TA0104.ai

Error Code

Detail

0
32768
32769
32770
32771
32772
32773
32774
32775
32776
32777
32778
32779
32780
32781
32782
32783
32784
32785
32786
32787
32788
32789
32790
32791
32792
32793
32794
32795
32796
32797
32798
32799
32800
32801
32802
32803
32804
32805
36863

No error
Unsupported header version
Abnormal header size
Abnormal manufacturer ID
Abnormal device family
Abnormal device revision
Abnormal vendor specification version
Abnormal number of modules
Abnormal number of bytes in module 1
Abnormal number of bytes in module 2
Device error in module 1
Checksum error in module 1
Checksum error in file
Unused
Write-prohibited area in FlashROM
Verification error during FlashROM writing
Polling error during FlashROM erasing
Polling time-out during FlashROM erasing
Polling error during FlashROM writing
Polling time-out during FlashROM writing
FlashROM driver undefined number error
File endcode error
File type error (UPDATE, ORIGINAL)
FlashROM driver undefined number error
On-start state error (other than DWNLD_NOT_READY)
Start segment error in module 1
Binary file error
Binary file error
Device error in module 2
Detection of EEPROM state other than backup after activation
Checksum error in module 2
Not in DWNLD_READY state when receiving GenericDomainInitiate
Not in DWNLD_OK state when receiving GenericDomainTerminate
Not in DOWNLOADING state when receiving GenericDomainSegment
Firmware error
Abnormal number of change in EEPROM
Abnormal change address in EEPROM
Control number error
Abnormal length of change data for EEPROM