<APPENDIX 1. LIST OF PARAMETERS FOR EACH BLOCK OF AV550G>

A-11

IM 11M12D01-61E

176

2176

CH8_MIN_VALUE

Denotes the minimum oxygen concentration of channel 8.

177

2177

CH8_MAX_VALUE

Denotes the maximum oxygen concentration of channel 8.

178

2178

CH8_AVE_VALUE

Denotes the average oxygen concentration of channel 8.

179

2179

CH8_MIN_DATE

Denotes the date and time when the minimum oxygen

concentration of channel 8 was calculated.

180

2180

CH8_MAX_DATE

Denotes the date and time when the maximum oxygen

concentration of channel 8 was calculated.

181

2181

CH1_SMART_CALIB_DA

TE

Denotes the recommended date of channel 1’s next

calibration.

182

2182

CH2_SMART_CALIB_DA

TE

Denotes the recommended date of channel 2’s next

calibration.

183

2183

CH3_SMART_CALIB_DA

TE

Denotes the recommended date of channel 3’s next

calibration.

184

2184

CH4_SMART_CALIB_DA

TE

Denotes the recommended date of channel 4’s next

calibration.

185

2185

CH5_SMART_CALIB_DA

TE

Denotes the recommended date of channel 5’s next

calibration.

Appendix1-3_6.ai

186

2186

CH6_SMART_CALIB_DA

TE

Denotes the recommended date of channel 6’s next

calibration.

187

2187

CH7_SMART_CALIB_DA

TE

Denotes the recommended date of channel 7’s next

calibration.

188

2188

CH8_SMART_CALIB_DA

TE

Denotes the recommended date of channel 8’s next

calibration.

189

2189

CH1_SEMIAUTO_CAL_S

TART

1 (stop)

AUTO

Determines whether to start or stop

calibrating

channel 1.

190

2190

CH2_SEMIAUTO_CAL_S

TART

1 (stop)

AUTO

Determines whether to start or stop

calibrating

channel 2.

191

2191

CH3_SEMIAUTO_CAL_S

TART

1 (stop)

AUTO

Determines whether to start or stop

calibrating

channel 3.

192

2192

CH4_SEMIAUTO_CAL_S

TART

1 (stop)

AUTO

Determines whether to start or stop

calibrating

channel 4.

193

2193

CH5_SEMIAUTO_CAL_S

TART

1 (stop)

AUTO

Determines whether to start or stop

calibrating

channel 5.

194

2194

CH6_SEMIAUTO_CAL_S

TART

1 (stop)

AUTO

Determines whether to start or stop

calibrating

channel 6.

195

2195

CH7_SEMIAUTO_CAL_S

TART

1 (stop)

AUTO

Determines whether to start or stop

calibrating

channel 7.

196

2196

CH8_SEMIAUTO_CAL_S

TART

1 (stop)

AUTO

Determines whether to start or stop

calibrating

channel 8.

197

2197

CH1_INDICATION_STAR

T

1 (stop)

AUTO

Determines whether to start or stop

checking the

indication of channel 1.

198

2198

CH2_INDICATION_STAR

T

1 (stop)

AUTO

Determines whether to start or stop

checking the

indication of channel 2.

199

2199

CH3_INDICATION_STAR

T

1 (stop)

AUTO

Determines whether to start or stop

checking the

indication of channel 3.

200

2200

CH4_INDICATION_STAR

T

1 (stop)

AUTO

Determines whether to start or stop

checking the

indication of channel 4.

201

2201

CH5_INDICATION_STAR

T

1 (stop)

AUTO

Determines whether to start or stop

checking the

indication of channel 5.

202

2202

CH6_INDICATION_STAR

T

1 (stop)

AUTO

Determines whether to start or stop

checking the

indication of channel 6.

203

2203

CH7_INDICATION_STAR

T

1 (stop)

AUTO

Determines whether to start or stop

checking the

indication of channel 7.

204

2204

CH8_INDICATION_STAR

T

1 (stop)

AUTO

Determines whether to start or stop

checking the

indication of channel 8.

205

2205

BLOWBACK_START

1 (stop)

AUTO

Determines whether to start or stop blowing back.

206

2206

CAL_GAS_PRESS_DRO

P_SW

1 (off)

AUTO

Sets the on or off state for a drop in the calibration gas

pressure.

207

2207

PROCESS_GAS_ALARM

_SW

1 (off)

AUTO

Sets the on or off state for process gas alarms.

semi-auto

semi-auto

semi-auto

semi-auto

semi-auto

semi-auto

semi-auto

semi-auto

semi-auto

semi-auto

semi-auto

semi-auto

semi-auto

semi-auto

semi-auto

semi-auto