Operation for demand measurement, Measuring operation, Operation for demand measurement -13 – Yokogawa PR300 Power and Energy Meter User Manual

Page 54

Advertising
background image

Operation for Display of Measurement Items and Measurement Method

4-13

IM 77C01E01-01E

1

2

3

4

5

A

4.7

Demand Measurement (Optional Measuring Function)

Operation for Demand Measurement

Demand measurement can be started and stopped by the operation key (

) or via communication.

This section only explains control by the operation key (for operation via communication, refer to the
PR300 Communication Interface User’s Manual: IM77C01E01-10E). In the demand measurement mode,
either the demand power or the demand current can be measured. To set either of these, refer to
Section 3.8, “Setting Demand Measurement Conditions.”

Hold down for at
least 3 seconds.

Measured Value screen

Start demand measurement

Stop demand measurement

Demand measurement starts.

The measured value is updated
every ten seconds.

Maximum demand value

Demand value

Hold down for at
least 3 seconds.

Turns on during
demand measurement.

Measured Value screen

Measured Value screen

Demand measurement stops.

During demand power or current
measurement

Does not turn on when
demand is not
measured.

Measured Value screen

Operation

Operation

Operation

Operation

NOTE

Once the operation key is used for control to start and stop demand measurement, it is the only

means for controlling until system reset* is performed. The same applies to control via communica-
tion.
* System reset can be performed by turning off/on the power supply for the PR300 or by executing

remote reset via communication.

When the system is reset, the measured values of demand, maximum demand, and demand alarm

status are reset to 0.

If power failure occurs during measurement, the measured values of demand, maximum demand,

and demand alarm status are reset to 0.

Example operation to start/stop demand measurement

Data

update

Data

update

Time

These control signals are invalid.

Start

command

Stop

command

Start

command

Start

command

Stop

command

These control signals are invalid.

This control
signal is valid.

System reset

The demand in this

period is measured.

The demand in this

period is measured.

Start

Start

Stop

Stop

Communication

Communication

Communication