AMX Modero NXT-1200V User Manual

Page 112

Advertising
background image

Firmware Pages and Descriptions

100

NXD/T-1200V 12" Modero® Video Wall/Flush Mount Touch Panel

The elements of the Sensor Setup page are described in the table below:

A light level value between the Minimum and Maximum DIM Mode values delivers an
average light level. The DIM mode Min Level can never exceed the DIM Mode Max
Level.

Sensor Setup Page Elements

Back:

Saves the changes and returns you to the previously active touch panel page.

Connection Status icon:

This visual display of the connection status allows the user to have a current
visual update of the panel’s connection status regardless of what page is
currently active.

• A Lock only appears on the icon if the panel has established a connection

with a currently secured target Master (requiring a username and password).

Light Sensor:

Allows you to monitor and alter the sensitivity of the Modero panel light sensor:

• The Light Sensor Level field indicates the level used to report the light

sensor level back to the NetLinx Master (set in TPD4) (read-only).

• The Light Sensor Level Port field indicates the port used to report the light

sensor level back to the NetLinx Master (set in TPD4) (read-only).

• The Light Sensor Channel field indicates the level used to report the sensor

channel back to the NetLinx Master (set in TPD4). It is On when you are
below the Maximum dim mode level (read-only).

• The Light Sensor Channel Port field indicates the port used to report the

sensor channel back to the NetLinx Master (set in TPD4) (read-only).

• The Light Level field provides a numeric value representing the current value

of the light level detected by the on-board photo-sensor.

• The Light Level bargraph displays a horizontal bargraph indicating the current

value of the light level detected by the on-board photo-sensor. This bargraph
provides a visual representation of the numeric value displayed within the
Light Level field.

• Use the Dim Mode Max Level bargraph to alter the Maximum DIM level

value used to activate the DIM Mode Brightness Level (range = 0 - 100).

• Use the Dim Mode Min Level bargraph to alter the Minimum DIM level value

used to activate the DIM Mode Brightness Level (range = 0 - 100).
- The position of this bargraph can never exceed that of the Dim Mode
Max Level.

Motion Sensor:

Provides the following fields:

• The Motion Detection field displays a reactive button that changes color

(illuminates) and displays the words "Motion Detected" when motion is
detected by the Modero panel’s front motion sensor.

• The Motion Sensor Port field indicates the port used to report the motion

sensor channel back to the NetLinx Master (set in TPD4) (read-only).

• The Motion Sensor Channel field indicates the channel used to report the

motion sensor channel back to the NetLinx Master (set in TPD4) (read-only).

Wake Panel On Motion
Sense:

The Wake Panel Sensitivity relates to the sensitivity of the motion sensor to
detect motion and wake the panel accordingly.

• Toggle the Enable/Enabled button to either active/inactive this feature:

- Enable - activates this feature. Activating this feature reactivates the
panel from a panel timeout (sleep) mode.
- Enabled - (illuminated when selected) deactivates this feature and
makes the panel use the specified Display Timeout value set on the
Setup Page.

• Use the Wake Panel UP/DN buttons to alter the sensitivity value.

- Range = 0 - 100.

• The horizontal WAKE PANEL SENSITIVITY bargraph indicates the current

motion sensitivity value associated with waking the panel from a timeout.

Advertising