Gsc ^gsn ^ico – AMX Modero NXT-1200V User Manual

Page 143

Advertising
background image

Programming

131

NXD/T-1200V 12" Modero® Video Wall/Flush Mount Touch Panel

"^" Button Commands (Cont.)

^GSC

Change the
bargraph slider
color or joystick
cursor color.

A user can also assign the color by Name and R,G,B value (RRGGBB or RRGGBBAA).

Syntax:

"'^GSC-<vt addr range>,<color value>'"

Variable:

variable text address range = 1 - 4000.

color value = Refer to theRGB Values for all 88 Basic Colors table on page 114.

Example:

SEND_COMMAND Panel,"'^GSC-500,12'"

Changes the bargraph or joystick slider color to Yellow.

^GSN

Change the
bargraph slider
name or joystick
cursor name.

Slider names and cursor names can be found in the TPDesign4 slider name and cursor
drop-down list.

Syntax:

"'^GSN-<vt addr range>,<bargraph slider name>'"

Variable:

variable text address range = 1 - 4000.

bargraph slider name = See table below.

Example:

SEND_COMMAND Panel,"'^GSN-500,Ball'"

Changes the bargraph slider name or the Joystick cursor name to ’Ball’.

^ICO

Set the icon to a
button.

Syntax:

"'^ICO-<vt addr range>,<button states range>,<icon index>'"

Variable:

variable text address range = 1 - 4000.

button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).

icon index range = 0 - 9900 (a value of 0 is clear).

Example:

SEND_COMMAND Panel,"'^ICO-500.504&510.515,1&2,1'"

Sets the icon for On and Off states for buttons with variable text ranges of 500-504 &
510-515.

Bargraph Slider Names:

Circle -M

None

Circle -S

Ball

Precision

Circle -L

Rectangle -L

Rectangle -M

Rectangle -S

Windows

Windows Active

Joystick Cursor Names:

Circle

None

Crosshairs

Arrow

Gunsight

Ball

Hand

Metal

Spiral

Target

View Finder